HDL Derated Metal
L-Shaped Heater

  • Excellent chemical resistance with stainless steel or titanium sheaths
  • Low watt density for long life: 35 w/in2 (5w/cm2) for standard watt density,
  • 17 w/in2 (2.5w/cm2) for deratedCorrosion resistant PP terminal enclosure
  • Grounded metal element
  • Voltages: 120, 208, 240, or 480
  • Thermal over-temperature protection:
  • P1 replaceable fuse up to 180° F
  • P4 replaceable fuse up to 230° F
  • P5 replaceable fuse up to 300° F
  • P2 resettable fuse up to 180° F
  • P6 resettable fuse up to 230° F
  • P7 resettable fuse up to 300° F

Resources

Contact Us to Order

Watts Volts Horizontal
in
Standard
Vertical
in
304
SS
316
SS
TITANIUM Ship Wt.
LBS
500
120
13
15
HDLF.5113Q-R*.**
HDLS.5113Q-R*.**
HDLT.5113Q-R*.**
10
240
HDLF.5213Q-R*.**
HDLS.5213Q-R*.**
HDLT.5213Q-R*.**
1000
120
17
19
HDLF1117Q-R*.**
HDLF1117Q-R*.**
HDLT1117Q-R*.**
11
240
HDLF1217Q-R*.**
HDLS1217Q-R*.**
HDLT1217Q-R*.**
1500
120
22
25
HDLF1.5122Q-R*.**
HDLS1.5122Q-R*.**
HDLT1.5122Q-R*.**
12
240
HDLF1.5222Q-R*.**
HDLS1.5222Q-R*.**
HDLT1.5222Q-R*.**
2000
240
26
25
HDLF2226Q-R*.**
HDLS2226Q-R*.**
HDLT2226Q-R*.**
13
480
HDLF2426Q-R*.**
HDLS2426Q-R*.**
HDLT2426Q-R*.**
2500
240
31
37
HDLF2.5231Q-R*.**
HDLS2.5231Q-R*.**
HDLT2.5231Q-R*.**
14
480
HDLF2.5431Q-R*.**
HDLS2.5431Q-R*.**
HDLT2.5431Q-R*.**
3000
240
36
50
HDLF3231Q-R*.**
HDLS3231Q-R*.**
HDLT3231Q-R*.**
15
480
HDLF3431Q-R*.**
HDLS3431Q-R*.**
HDLT3431Q-R*.**
4000
240
44
50
HDLF4244Q-R*.**
HDLS4244Q-R*.**
HDLT4244Q-R*.**
18
480
HDLF4444Q-R*.**
HDLS4444Q-R*.**
HDLT4444Q-R*.**
4500
240
50
50
HDLF4.5250Q-R*.**
HDLS4.5250Q-R*.**
HDLT4.5250Q-R*.**
20
480
HDLF4.5450Q-R*.**
HDLS4.5450Q-R*.**
HDLT4.5450Q-R*.**
5000
240
55
50
HDLF5255Q-R*.**
HDLS5255Q-R*.**
HDLT5255Q-R*.**
22
480
HDLF54551Q-R*.**
HDLS54551Q-R*.**
HDLT54551Q-R*.**
6000
240
64
50
HDLF6264Q-R*.**
HDLS6264Q-R*.**
HDLT6264Q-R*.**
25
480
HDLF6464Q-R*.**
HDLS6464Q-R*.**
HDLT6464Q-R*.**
HDL Derated Metal L-Shaped Heater Specs 1
Series Wattage Voltage Horizontal
Length
Vertical
Length
Riser Option Type of Protector Wire & Conduit Length
HDLP = Steel
.5 = 500
1 = 120
13 = .5kW
R15 = .5kW
blank = 90° horizontal bend
Replaceable Fuse
36″ length standard
HDLF = 304 SS
1 = 100
2 = 240
17 = 1kW
R19 = 1kW
S = straight riser
P1 = solutions up to 190°F
Specify variations from standard Ex: -X84 = 84″
HDLS = 316 SS
1.5 = 1500
3 = 380
22 = 1.5kW
R25 = 1.5kW
P4 = solutions up to 230°F
HDLT = Titanium
2 = 2000
4 = 480
26 = 2kW
R25 = 2kW
P5 = solutions up to 300°F
2.5 = 2500
5 = 415
31 = 2.5kW
R37 = 2.5kW
Resettable Fuse
3 = 3000
6 = 600
36 = 3kW
R50 = 3kW
P2 = solutions up to 190°F
4 = 4000
7 = 400
44 = 4kW
R50 = 4kW
P6 = solutions up to 230°F
4.5 = 4500
8 = 208
50 = 4.5kW
R50 = 4.5kW
P7 = solutions up to 300°F
5 = 5000
9 = 220
55 = 5kW
R50 = 5kW
6 = 6000
0 = 200
64 = 6kW
R50 = 6kW
HDL Derated Metal L-Shaped Heater Specs 2

Headquarters

 

117 S Kentucky Ave., Suite B

Evansville, Indiana 47714

(812) 962-5770

Sales@Heatertek.com

Idaho Location

 

9530 W Bethel Ct., Suite B

Boise, Idaho 83709

(208) 323-6143

Sales@Industrialheatingsystems.com