Home Product H3V Three Element Metal Deep Tank Heater

H3V Three Element Metal Deep Tank Heater

Industrial Metal Heaters for Optimal Performance and Durability

Our industrial metal heaters are designed to meet the most demanding applications, offering exceptional chemical resistance with your choice of durable stainless steel or titanium sheaths. These materials ensure reliable performance even in corrosive environments, making them an ideal solution for your industrial heating needs.

 

  • Low Watt Density for Extended Lifespan:
    • Standard watt density: 35 w/in² (5 w/cm²)
    • Derated watt density: 17 w/in² (2.5 w/cm²) for applications requiring reduced power intensity. (Other watt densities available.)
  • Corrosion-Resistant Terminal Enclosure: The polypropylene (FRPP) terminal enclosure provides enhanced protection against environmental corrosion.
  • Grounded Metal Element: For improved safety and operational efficiency.
  • Advanced Over-Temperature Protection: Safeguard your equipment with replaceable and resettable fuses designed for various temperature thresholds to help protect equipment against low solution level conditions
  • Versatile Voltage Options: Available in multiple voltage configurations to suit diverse requirements: 120V, 208V, 240V, or 480V. (Other voltages available.)
  • Optional welded metal terminal enclosure: Provides maximum moisture resistance. Only for use with resettable thermal protection devices. Significantly enhances heater performance for hot temperature and large kW applications.
  • Advanced Thermal Over-Temperature Protection: Safeguard your equipment with replaceable or resettable fuses designed for various temperature thresholds:
    • Replaceable Fuses:
      • P1: Up to 180°F
      • P4: Up to 230°F
      • P5: Up to 300°F
    • Resettable Fuses:
      • P2: Up to 180°F
      • P6: Up to 230°F
      • P7: Up to 300°F

Key facts

Watts Volts Three Tube
Length
in
304
SS
316
SS
TITANIUM
18000
240
36
H3VF18236-**
H3VS18236-**
H3VT18236-**
480
H3VF18436-**
H3VS18436-**
H3VT18436-**
24000
240
44
H3VF24344-**
H3VS24344-**
H3VT24344-**
480
H3VF24444-**
H3VS24444-**
H3VT24444-**
27000
480
50
H3VF27450-**
H3VS27450-**
H3VT27450-**
30000
480
55
H3VF30455-**
H3VS30455-**
H3VT30455-**
36000
480
64
H3VF36464-**
H3VS36464-**
H3VT36464-**
45000
480
77
H3VF45477-**
H3VS45477-**
H3VT45477-**
48000
480
82
H3VF48482-**
H3VS48482-**
H3VT48482-**
54000
480
91
H3VF54491-**
H3VS54491-**
H3VT54491-**
Series Wattage Voltage Overall
Length
Phase Type of Protector Wire & Conduit Length
H3VP = Steel
18 = 18000
1 = 120
36 = 18kW
1 = Single phase
Replaceable Fuse
6’ length standard
H3VF = 304 SS
24 = 24000
2 = 240
44 = 24kW
3 = Three phase
P1 = solutions up to 190°F
Specify variations from standard Ex: -X84 = 84″
H3VS = 316 SS
27 = 27000
3 = 380
50 = 27kW
P4 = solutions up to 230°F
H3VT = Titanium
30 = 30000
4 = 480
55 = 30kW
P5 = solutions up to 300°F
36 = 36000
5 = 415
64 = 36kW
Resettable Fuse
45 = 45000
6 = 600
77 = 45kW
P2 = solutions up to 190°F
48 = 48000
7 = 400
82 = 48kW
P6 = solutions up to 230°F
54 = 54000
8 = 208
91 = 54kW
P7 = solutions up to 300°F
9 = 220
0 = 200

Contact