Home Product H3F, H3S, & H3T Triple Tube Over the Side Metal Heater

H3F, H3S, & H3T Triple Tube Over the Side Metal Heater

Industrial Metal Heaters for Optimal Performance and Durability

Our industrial metal heaters are designed to meet the most demanding applications, offering exceptional chemical resistance with your choice of durable stainless steel or titanium sheaths. These materials ensure reliable performance even in corrosive environments, making them an ideal solution for your industrial heating needs.

 

  • Low Watt Density for Extended Lifespan:
    • Standard watt density: 35 w/in² (5 w/cm²)
  • Corrosion-Resistant Terminal Enclosure: The polypropylene (FRPP) terminal enclosure provides enhanced protection against environmental corrosion.
  • Grounded Metal Element: For improved safety and operational efficiency.
  • Advanced Over-Temperature Protection: Safeguard your equipment with replaceable and resettable fuses designed for various temperature thresholds to help protect equipment against low solution level conditions
  • Versatile Voltage Options: Available in multiple voltage configurations to suit diverse requirements: 120V, 208V, 240V, or 480V. (Other voltages available.)
  • Optional welded metal terminal enclosure: Provides maximum moisture resistance. Only for use with resettable thermal protection devices. Significantly enhances heater performance for hot temperature and large kW applications.
  • Advanced Thermal Over-Temperature Protection: Safeguard your equipment with replaceable or resettable fuses designed for various temperature thresholds:
    • Replaceable Fuses:
      • P1: Up to 180°F
      • P4: Up to 230°F
      • P5: Up to 300°F
    • Resettable Fuses:
      • P2: Up to 180°F
      • P6: Up to 230°F
      • P7: Up to 300°F

Key facts

Watts Volts Hot
Zone
in
Overall
Length
in
304
SS
316
SS
TITANIUM Ship Wt.
LBS
3000
240
6
11
H3F3211-*-**
H3S3211-*-**
H3T3211-*-**
21
480
H3F3411-*-**
H3S3411-*-**
H3T3411-*-**
6000
240
10
17
H3F6217-*-**
H3S6217-*-**
H3T6217-*-**
30
480
H3F6417-*-**
H3S6417-*-**
H3T6417-*-**
9000
240
16
23
H3F9223-*-**
H3S9223-*-**
H3T9223-*-**
33
480
H3TF423-*-**
H3TS423-*-**
H3T9423-*-**
12000
240
20
29
H3F12229-*-**
H3S12229-*-**
H3T12229-*-**
39
480
H3F12429-*-**
H3S12429-*-**
H3T12429-*-**
15000
240
25
35
H3F15235-*-**
H3S15235-*-**
H3T15235-*-**
45
480
H3F15435-*-**
H3S15435-*-**
H3T15435-*-**
18000
240
30
40
H3F18240-*-**
H3S18240-*-**
H3T18240-*-**
51
480
H3F18440-*-**
H3S18440-*-**
H3T18440-*-**
24000
240
37
47
H3F24247-*-**
H3S24247-*-**
H3T24247-*-**
63
480
H3F24447-*-**
H3S24447-*-**
H3T24447-*-**
27000
480
44
54
H3F27454-*-**
H3S27454-*-**
H3T27454-*-**
69
30000
480
49
59
H3F30459-*-**
H3S30459-*-**
H3T30459-*-**
75
36000
480
58
68
H3F36468-*-**
H3S36468-*-**
H3T36468-*-**
84
Series Wattage Voltage Overall
Length
Phase Type of Protector Wire & Conduit Length
3HP = Steel
3 = 3000
1 = 120
11 = 3kW
1 = Single phase
Replaceable Fuse
6’ length standard
3HF = 304 SS
6 = 6000
2 = 240
17 = 6kW
3 = Three phase
P1 = solutions up to 190°F
Specify variations from standard Ex: -X84 = 84″
3HS = 316 SS
9 = 9000
3 = 380
23 = 9kW
P4 = solutions up to 230°F
3HT = Titanium
12 = 12000
4 = 480
29 = 12kW
P5 = solutions up to 300°F
15 = 15000
5 = 415
35 = 15kW
Resettable Fuse
18 =18000
6 = 600
40 = 18kW
P2 = solutions up to 190°F
24 = 24000
7 = 400
47 = 24kW
P6 = solutions up to 230°F
27 = 27000
8 = 208
54 = 27kW
P7 = solutions up to 300°F
30 = 30000
9 = 220
59 = 30kW
36 = 36000
0 = 200
68 = 36kW

Contact

If you have any questions about our products or need expert assistance with your purchase, our team is here to help. Feel free to contact our experienced and knowledgeable team by phone, email, or through the online contact form above.